Motor data are immediately read out when staring the commissioning assistant of the 8200 vector/motec (remedied from V4.7)

Remedied from?
GDC 4.7 and GDC easy 4.7

Behaviour of the new version?
When starting the commissioning assistant the online communication is not activated immediately. As a result, the motor data (codes C0089 and C0090) are not read out from the controller.



Which products are affected?
GDC 4.6.1 and GDC easy 4.5

What happens?
When starting the commissioning assistant the online communication is activated immediately and the motor data (codes C0089 and C0090) are read out from the controller.

When does the problem occur?
Immediately after starting the commissioning assistant.

Possible diagnostics?
If a parameter set is loaded from a file and the commissioning assistant is opened afterwards, codes C0089 and C0090 are read from the drive controller. As a result, the following consequence occurs when writing the current parameter set to the drive afterwards. The values of the two codes mentioned above do not correspond to the values of the file called before but to the values which had been saved in the drive controller before. This behaviour also occurs when opening a parameter set file through a double click if the commissioning assistant is automatically opened when starting GDC.

Short-term measures/recommendations?
The automatically stated commissioning assistant can be deactivated under Options => Desktop. Codes C0089 and C0090 can be corrected subsequently.

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/200414111/1/
Contact form