No PDO receipt of data after program download (elimination)

Which products are affected?
EVS93xx-EI (Servo PLC, software version 2.3)
EVS93xx-ET (Servo PLC, software version 2.3)
EPL 10200 (Drive PLC, software version 6.1)

Function restriction corrected
Data of external devices can be received after a DDS project download via function block L_CanPdoReceive.
 
Which products are affected?
  • EVS93xx-EI (Servo PLC version 2.x and 6.0)
  • EVS93xx-ET (Servo PLC version 2.x and 6.0)
  • EPL-10200 (Drive PLC version 2.x and 6.0)

How is the reaction?
With function block L_CanPdoReceive from the library LenzeCanDrv.lib no data can be received.

When does the problem occur?
After a DDS-project download it can happen that with the function block L_CanPdoReceive no data can be received.

Possible diagnostics?
No.

Short-term measures/recommendations?
If after a DDS-project download a mains connection of the control follows, data can be received with the function block L_CanPdoReceive.  