REF-OK and absolute positioning with saving

Which products are affected?

9300EP servo positioning controller version V2.1

What happens?

In positioning mode 'Absolute positioning with saving' (C1210 = 2) the controller always initialised with home position known (REF-OK = 1), even if no homing had taken place yet.

When does the problem occur?

After the first mains connection during the initial commissioning procedure.

Possible diagnostics?

Request status REF-OK at the control end.

Short-term measures/recommendations?

During the initial commissioning procedure and after any faults in which the homing position lost, perform a homing from the control end.

Evaluation:

Normally a homing can be started from the control end if required.

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/20035109/1/