The current controller setting does not depend on the motor selected (elimination)
Which products are affected?
EVS93xx-EI (Servo PLC Version 2.2)
EVS93xx-ET (Servo PLC Version 2.2)
Eliminated function restriction:
When a motor is selected via code position C0086, code positions C0075 (Vp current controller) and C0076 (Tn current controller) are also adapted accordingly.