Integration of Brake Energy Management to Reduce the DC link Voltage
Functional Enhancement:
Reduction of the DC link voltage through the implementation of braking energy management when F3E is deactivated. A possible cause for F3E deactivation is a voltage dip followed by an overshoot in the mains voltage, which causes an increase in the DC link voltage.The increased DC link voltage can now be reduced using the“Inverter-Motor-Brake” functionality, allowing F3E to become active again.
The parameter settings and description can be found in the manual under 14.2 Braking Energy Management.
Taxonomy:
i550 motec frequency inverters
,
i5x0 motec frequency inverters
,
i650 motec frequency inverters
,
i6x0 motec frequency inverters
AKB-ID:
202600412
Last update:
2026/09/10