Calculation of Id and Iq Controllers

     


 

 

Fixed as of: 

 

Behavior of the new version: 

The switching frequency for SLSM-PSM remains fixed at 8 kHz. However, the customer should be able to choose between an 8-kHz 3-switch configuration and an 8-kHz 2-switch configuration.


Description of the behavior: 

When control mode 0C2C00:000 = SLSM-PSM [8] is selected, switching the switching frequency does not work.
The 8-kHz drive option is always used, regardless of the setting in 0C2939:000. This is also the case outside of RF injection.
 
In the Drive Package with IE++, the specified power is not available with the iSM.