Fixed as of:
L_TS2P_TechModulesSynchronizingCamming (from V3.33.0)
(Update via Easy Package Manager)
Behavior of the new version;
The L_TS2P_FlexCamState moves the cam disc as desired after a cam disc change.
Description of behavior:
The L_TS2P_FlexCamState technology module moves the cam disc incorrectly after a
cam disc change.
Conditions under which the behavior occurs;
Two different cam discs are run through one after the other.
- After the first cam disc has been traversed, the second cam disc is selected.
- The resulting x-position calculated from the scaled master position is outside the cam disc.
Affected products;
FlexCAM technology module (L_TS2P_FlexCAMState from library L_TS2P_TechModulesSynchronizingCamming)
Short-term measures, Recommendations, evaluation:
When changing curve writing with an active scaling factor,
relative reference between the position of the master axis and the
cam disc xMasterAbsolute = FALSE
[Automatic Translation]