Error messages when compiling a project for 'i950 Extended for customer-specific devices only'
Corrected from:
-
Behavior of the new version: -
Description of behavior: When compiling a project in PLC Designer, the following compiler errors occur:
[ERROR] visuelembase, 4.8.0.0 (system): Visu_FbClearEventsAfterStart: C0086: No definition found for interface 'CmpEventMgr_Interfaces.ICmpEventCallback'
[ERROR] visuelembase, 4.8.0.0 (system): Init [Visu_FbClearEventsAfterStart]: C0032: Cannot convert type 'VISU_FBCLEAREVENTSAFTERSTART(visuelembase, 4.8.0.0 (system))' to type 'CmpEventMgr_Interfaces.ICmpEventCallback'
[ERROR] visuelembase, 4.8.0.0 (system): Init [Visu_FbClearEventsAfterStart]: C0032: Cannot convert type 'CmpEventMgr_Interfaces.ICmpEventCallback' to type 'ICmpEventCallback(cmpeventmgr, 3.5.12.0 (system))'
Conditions under which the behavior occurs: The above compiler error messages occur when a project with an 'i950 Extended for customer specific devices only' is created in combination with a CODESYS WebVisu with a PLC Designer lower than V4.1 and then opened in PLC Designer V4.1.
Affected products: PLC Designer V4.1
Short-term measures, recommendations, evaluation: Continue to edit affected projects with a PLC Designer version ≤ V4.0.1.