DDH (Drives Datahub) - 8400 Oscilloscope function does not work with maximum possible resolution

To use the maximum number of data points in the oscilloscope recordings, it is necessary to create the configuration file (*.los file) so that it does not contain any measurements.

The Lenze EASY Starter is used to create the *.los file; the file can be saved in the EASY Starter before or after executing an oscilloscope recording. *los files that are saved after a recording may use different configuration settings ("Sample rate" and "Time base") than the initially set values.

It is recommended to save the oscilloscope configuration file (*.los) directly after entering the configuration data in the EASY Starter interface and to use it in this form with the Drives DataHub. 


Fixed functional restrictions: 
  •  It is now possible to use the max. resolution in the oscilloscope function in conjunction with the 8400.

Compatibility with previous versions:  

Existing functionality of the previous version behaves the same (downward compatible). 


[Automatic Translation]

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/202500079/1/
Contact form