I950ES: Signals do not switch safe output SD-Out1 (fixed as of V01.03.08)
Corrected from: V01.03.08
Behavior of the new version:
All setting options for the secure output SD-Ou1 work.
Description of the behavior:
The safe output SD-Out1 of the i950ES can be wired with various signals. Feedback from the field has shown that not all possible settings work. The error occurs with both settings (positive and negative logic).
The following setting options are affected:
0x2886:000 "SHom active"- Output
0x2887:000 "SHom available" - Output
0x28AD:000 "RMS active" - Output
0x28B1:000 "SMS observed" - Output
Conditions under which the behavior occurs:
SD-Out1 is parameterized to one of the above signals.
Affected products: i950 ES all Safety FW versions
Short-term measures, Recommendations, evaluation:
Evaluate affected signals via status word in PLC or safety controller.