Encoder module only present in SlotB: An incorrect temperature value is displayed under 0x2D49:12, temperature evaluation is not plausible (corrected from V01.08.00)

Corrected from:
Servo Inverter i950 FW: from V01.08.00
 
Response of the new version:
Now the temperature fed back via the load sensor is correctly displayed via parameter 0x2D49:12.


 
What happens?
A wrong temperature value is displayed under parameter 0x2D49:12 if a separate load encoder is parameterised (0x2D49:10 = "Motor encoder and load encoder [3]").

When does the behaviour occur?
  • OCT encoder in use and 
  • both motor encoder and load encoder are selected as temperature feedback (0x2D49:10 = [3].
Which products are affected?
Servo Inverter i950 FW
 
Short-term measures / evaluation / recommendations: