i950 unit type BF5: Error message 0xFF41 'Error charging circuit' sporadically occurs when switching on the unit (corrected from V01.08.00)

Corrected from:
Servo Inverter i950 FW: from V01.08.00
 
Response of the new version:
When switching on, the described error message no longer occurs erroneously.

 
What happens?
The error message 0xFF41 "Error charging circuit" occurs sporadically when switching on the mains.

When does the behaviour occur?
  • At first, only the 24V supply is switched on at the unit so that the unit boots up and
  • only then is the power supply switched on.
Which products are affected?
Servo Inverter i950 FW (only BF5 units affected)
 
Short-term measures / evaluation / recommendations:
The error message can be reset.
A workaround is to first switch on the power supply of the unit and only then switch on the 24V supply.


Automatic Translation

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/202200222/1/
Contact form