The Lenze c520, c550 and c750 controllers support secure communication when accessing the FAST UI Runtime web-visu.
Safe communication is activated when an instance of the function block L_IPAP_ChangeHttpsRedirectSetting4EasyUI from the library L_IPAP_ParameterManagerAccess is called in the PLC program, whose input 'eHttpsRedirectSetting' is assigned the enum value 'ENABLE_HttpsRedirect' and the input xExecute is set to TRUE. This sets the parameter 0x5901/2 to 1.
The certificate used by the controller is a self-signed certificate. The validity can be checked using the certificate fingerprint in parameter 0x5901/1. Since the certificate is bound to the controller's hardware, the authenticity of the certificate must be checked and confirmed again when replacing the device.
Contained in which products? Cabinet Controller c520 from V1.7
Cabinet Controller c550 from V1.7
Cabinet Controller c750 from V1.7
Application:
Secure communication between Lenze controller and visualisation.