OPC-UA: Changed data type when accessing TIME variables

Function extension:
The data type TIME is no longer transmitted as UINT32 data type during an OPC-UA connection, but now as INT64 data type. Due to the extension, the data type must be adapted to INT64 when using the TIME data type, e.g. in a visualisation.
This change does not lead to any incompatibilities within the PLC project.

Contained in which products?
Cabinet Controller c300 as of V3.20
Cabinet Controller 3200C as of V3.20
Panel Controller p300 from V3.20
Panel Controller p500 from V3.20
Cabinet Controller c520 from V1.5
Cabinet Controller c550 from V1.5
Cabinet Controller c750 as of V1.5

Application:
This adaptation increases compatibility between different manufacturers, as the TIME data type is not specified in IEC 61131 and can therefore accept different data types.