Function extension:
In the index Parameter set information: CRC Safety module w/o safety adress 0x2115:8 the checksum is displayed, which was calculated corresponding formed to the safety parameterization. The safety address is not included.
Contained in which products?
Servo inverter i950 base firmware from V01.04.01
Only applies to i950 Extended Safety
Application:
Diagnostic parameters to detect whether the same safety parameterization is present in axes of a system with the same functional use.