Commissioning function for Hiperface linear encoder TTK50, TTK70 (from V01.04.01)

Function extension:
Hiperface SinCos absolute value encoder:  For special types of linear Hiperface encoders from the manufacturer Sick (TTK50, TTK70), it is necessary to set the start position of the magnatic tape, which is scanned, during commissioning.
This adjustment function can be performed with the newly implemented Axis commands:
  • Axis command 0x2822:38   (motor encoder slotA, left side)
  • Axis command 0x2822:39   (load encoder slotB, right side).

Contained in which products?
i950 servo inverter FW:  from  V01.04.01.1471

Application:
Adjustment between read head and magnetic tape in special Linear Hiperface Encoders from Sick. These encoders are typically used in conjunction with linear motors.