What happens?
Loading or downloading a device application (LDA file) with the EASY Starter from or to an i950 Servo Inverter is aborted with the following error message:
No connection could be established because the target computer refused the connection.
When does the behaviour occur?
The error message described above occurs when attempting to transfer or load a device application from the EASY Starter with a controller as the gateway to an i950 servo inverter.
Which products are affected?
Cabinet Controller c300 ab V3.17
Cabinet Controller 3200C ab V3.17
Panel Controller p300 ab V3.17
Panel Controller p500 ab V3.17
Short-term measures
Transfer the device application directly via the Ethernet interface of the Servo Inverter i950 without using the controller as a gateway.
Evaluation/Recommendations:
The Lenze controller cannot be used as a gateway to load or download a device application (LDA file) from the EASY Starter to an i950 servo inverter connected to the controller via EtherCAT.