Load TA default settings: Falsely executable with enabled controller (corrected from V01.04.01)

Corrected from:
Servo Inverter i950 FW:  from V01.04.01.1471
 
Response of the new version:
Loading the default settings for the technology application (TA) is now only possible when the converter is in the locked state.
 
What happens?
When the inverter is enabled, loading of the default settings for the technology application (TA) is possible by mistake. In this state, loading is incomplete and the warning "Loading 'factory-settings' incomplete" (error number 0x28011202) is triggered.
 
When does the behaviur occur?
Loading the default settings for the TA when the inverter is enabled.

Which products are affected?
Servo-Inverter i950 FW
 
Short-term Measures / Evaluations / Recommendations:
Only load the default settings for the technology application (TA) when the inverter is locked.