Motor temperature detection: PT1000 temperature sensor can be set under 0x2D49:1 (from V2.10.12)

Function extension:
The i700 servo inverter now also supports PT1000 temperature sensors for detecting the current motor temperature.
The following selections for PT1000 were added to the parameter 0x2D49:1 (0x3549:1) 'Motor temperature monitoring: Sensor type':
0:  KTY83-110
1:  KTY83-110 + 2xPTC 150°C
2:  KTY84-130
3:  Special characteristic
4:  Res.
5:  PT1000
6:  PT1000 + 2xPTC
Contained in which products?
i700 servo inverter,  series devices (V02.x):  from V02.10.12.11906
                                  existing devices (V01.x):  from V01.10.12.11905
 
Application:
Many manufacturers have discontinued KTY temperature sensors. Accordingly, KTY temperature sensors are virtually no longer available. 
For this reason, in the future, Lenze motors will no longer be equipped with the KTY temperature sensors used so far, but with PT1000 temperature sensors.