Corrected from:
Inverter Drives 8400 StateLine, HighLine, and TopLine from firmware version 14.00.00.00
and a Profinet module from FW version 02.06 onwards
Which products are affected?
8400 StateLine, HighLine, and TopLine: FW version < 13.00.00.00 and a Profinet module with a FW version ≤ 02.01.
What happens?
The string codes C13899/1…8 for the station name cannot be written to.
When does the problem occur?
String codes of the Profinet module cannot be written to.
Diagnostics options?
Inter alia, this response can be observed with regard to the online change of parameters C13899/1…8 in the Engineer parameter list.
Short-term measures/recommendations?
None.
Evaluation:
The Profinet module cannot be indicated by a station name in the codes.