Incorrect unit of display parameters C837/20+28 of L_PhaseIntK
Corrected from:
Inverter Drives 8400 HighLine V16.00.00, in the Engineer ≥ V02.22
Inverter Drives 8400 TopLine V16.00.00, in the Engineer ≥ V02.22
Response of the new version:
In the dialog and in the parameter list, the unit of the display parameters C837/20 and C837/28 is displayed in [inc/ms] as expected.
What happens?
The unit of the display parameters of the phase difference input signal of the L_PhaseIntK_x blocks is not, as expected, displayed in [inc/ms] but in [rpm].
When does this behaviour occur?
The behaviour occurs in the parameter list and in the block dialogs in the Engineer.
Which products are affected?
Inverter Drives 8400 HighLine < V16.00.00, in the Engineer <V02.22
Inverter Drives 8400 TopLine < V16.00.00, in the Engineer <V02.22
Short-term measures:
The displayed value has the reference: 15000 rpm correspond to 16384 inc/ms.
Evaluation/recommendations:
The incorrect unit display is misleading in diagnostics scenarios including the display parameters. The block function is not influenced.
Taxonomy:
8400 HighLine frequency inverters
,
8400 TopLine frequency inverters
AKB-ID:
201500464
Last update:
2023/09/13
Category:
Version Informations