8400 StateLine, HighLine and TopLine: FW version ≤ 13.00.00.00
What is the response?
No keypad texts for bit codes are shown.
When does the problem occur?
For the following types of codes there are no keypad texts for the individual bits:
Configuration codes of FW functions, which can be set bit by bit (e.g. C1297 L_MckCtrlInterface alternative functions)
Status codes of blocks or FW functions, the states of which can be itemised bit by bit (e.g. C1299 MCK MCKInterface status)
Signal states of binary module inputs and outputs (e.g. C833)
Diagnostics options?
Display of the above-mentioned example code in the keypad.
Short-term measures/recommendations?
None.
Evaluation:
Especially the configuration of FW functions which are partly used to set compatibility parameters, cannot be executed with the keypad without an additionally supplied documentation.
Taxonomy:
8400 StateLine frequency inverters
,
8400 HighLine frequency inverters
,
8400 TopLine frequency inverters
AKB-ID:
201304887
Last update:
2023/09/09
Category:
Version Informations