Remedied from:
GDC V4.13, GDCeasy V4.13
Behaviour of the new version?
GDC V4.13 is used to install a rectified PDB file for 9300 Servo PLC V8.x.
Which products/versions are affected?
GDC V4.12 in combination with 9300 Servo PLC V8.x and CANopen Modul 2178IB
What happens? When does the problem occur?
If the 9300 Servo PLC Version 8 with 2178IB CANopen module is selected in GDC V4.12, the parameter set cannot be opened. The following error messages appear in a message window while opening the parameter set:
953: There is not this parameter at '000'
954: There is not this parameter at '000'
986: There is not this parameter at '005'
987: There is not this parameter at '006'
993: There is not this parameter at '000'
994: There is not this parameter at '001'
995: There is not this parameter at '002'
996: There is not this parameter at '003'
997: There is not this parameter at '004'
1004: There is not this parameter at '000'
1005: There is not this parameter at '001'
1006: There is not this parameter at '002'
1007: There is not this parameter at '000'
1008: There is not this parameter at '000'
1039: There is not this parameter at '006'
1094: There is not this parameter at '001'
1170: There is not this parameter at '000'
1171: There is not this parameter at '002'
Cause: Code positions, to which the device description of 2178 V2.0 refers, are missing in the device description for 9300 Servo PLC V8.x.