PS01 error message during operation (eliminated from V5.0 onwards)
Eliminated from:
StateLine with firmware version V05.01 or higher
Behaviour of the new version?
This function restriction is eliminated with the above-mentioned firmware version.
Which products are affected?
8400 StateLine with FW < 05.01
What happens?
During operation, the 'PS01 – No memory module' error message is sporadically issued although the memory module is properly available in the device.
When does the problem occur?
When an 8400 StateLine has been connected to a CAN bus with a pending CAN sync signal.
Possible diagnostics?
Logbook entry
Short-term measures / recommendations?
None (switch-off CAN sync if necessary)
Evaluation:
PS01 is a warning which leads to Logbook entries and warnings but does not limit the operational performance of the inverter.