wMaxMotorSpeed at the LS_MotorInterface does not display anything (eliminated from V5.0 onwards)

Eliminated from:
StateLine / HighLine with firmware version V05.01 or higher

Behaviour of the new version?
This function restriction is eliminated with the above-mentioned firmware version. The value is displayed.



Which products are affected?
8400 StateLine / HighLine with FW < 05.01

What happens?
Incorrect diagnostics / interpretation of the system block output by the user

When does the problem occur?
When the wMaxMotorSpeed output is used at the LS_MotorInterface

Possible diagnostics?
The wMaxMotorSpeed output does not display the speed set in C0011.

Short-term measures / recommendations?
Determine the reference speed via L_ParRead from C0011.

Evaluation:
The defective display is detected during commissioning.

Information taken from chapter 1.1.1 of Service Message No. 16/2010.