Codes of the data type OCTET_STRING in the Inverter Drive 8400 cannot be written (remedied from V4.5)

Eliminated from:
L-force Loader V4.5

Behaviour of the new version?
During the download, the L-force Loader V4.5 also supports codes with the data type OCTET_STRING.
An export of codes with the data type OCTET_STRING is only supported from the L-force Engineer V2.10 SP3 onwards.



What is the reaction?
The L-force Loader cannot write codes of the data type OCTET_STRING, e. g. the code C13914 (Profinet module: I&M4 sginature).

When does the problem occur?
The reaction described above occurs if the code C13914 in the Inverter Drive 8400 is written.

Which products are affected?
L-force Loader V4.4
Inverter Drive 8400

Diagnostics options?
None

Short-term measures/recommendations?
Use the L-force Loader V4.5. for download

Evaluation:
Code C13914 of the 8400 Profinet module cannot be written.

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/201002744/1/