Eliminated from:
L-force Loader V4.5
Behaviour of the new version?
The L-force Loader V4.5 transmits codes of the Inverter Drive without any rounding errors.
What is the reaction?
When a code is written, the value of the code will be rounded.
When does the problem occur?
The problem described above occurs in case of codes
- with a factor higher 1 (codes with decimal positions)
and
- either has the data type INTEGER_32 or UNSIGNED_32
and
- to which a value with more than 6 digits is transferred.
Which products are affected?
L-force Loader V4.4
Inverter Drive 8400
Diagnostics options?
None
Short-term measures/recommendations?
Use the L-force Loader V4.5. for download
Evaluation:
The functional restriction may cause rounding errors during the transfer of code values to an Inverter Drive 8400. This function restriction is eliminated with the L-force Loader V4.5.