Stipulation of torque limits by means of process data
Functional description
The positive and negative torque limit can now be stipulated with the help of indices I-60E0 and I-60E1 by means of the process data. Previously, this was only possible via the parameter channel.
Applications
Depending on the process, it can make sense to alter the pos. and neg. torque limits during ongoing operation.
Note:
Given that stipulation of the torque limits by means of process data was not possible in the case of the 9400 StateLine, the limits could be stipulated in the respective codes by means of the parameter channel of the fieldbus system or directly by means of Engineer. This is no longer possible. The limits can only be stipulated by means of the process data because they exist in the form of mappable objects. If these limits are not stipulated by means of the process data, the two limits are active with default values of 100 %.
Contained in which products/versions?
9400 HighLine FV 7.x TA CiA 402