Control factor of field weakening for synchronous machines not detectable (remedied from V5.0)

Remedied from?
9400 HighLine SW V5.0
not eliminated at 9400 StateLine SW ≤ V4.0

Eliminated function restriction
The current motor flux is displayed via the MI_dnActualFlux_n and Common.dnActualFlux variables. Among other things the user can determine the degree of field weakening of the motor via these variables. The greater the field weakening, the smaller is the value of these variables. So far this value has always remained at 100%, even for the field weakening of synchronous machines. The MI_dnActualFlux_n and Common.dnActualFlux variables have been revised to display the correct degree of field weakening for synchronous machines, too.

Published with Service Message No. 18/2009