Function block L_GainOffsetPhi and L_OffsetGainPhi - Faulty calculation (remedied from V2.0 onwards)

Remedied from:
8400 HighLine   SW V2.00 onwards

Behaviour of the new version?
The above-named software version rectifies this functional restriction.




Which products are affected?
8400 HighLine   SW ≤ V1.00

What happens?
When the function blocks 'L_GainOffsetPhi' and 'L_OffsetGainPhi' are used, faulty internal calculations appeared. Concrete circumstances causing this problem cannot be specified any further.

When does the problem occur?
The problem occurs when the 'L_GainOffsetPhi' and 'L_OffsetGainPhi' function blocks are used.

Possible diagnostics?
None.

Short-term measures/recommendations?
Convert value for instance via an external control

Evaluation:
The function block should not be used. This function restriction can be eliminated by applying the recommendations mentioned before.

Published with service message No. 2009/02

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/200902759/1/