Er255/OC9-TRIP by switching off a mains contactor (elimination)

Which products are affected?
Motor starter starttec SW2.1

Eliminated function restriction
When a motor starter starttec was switched off by a mains contactor, another starttec, which was inhibited and connected to the mains (24 V control voltage and mains voltage were applied), could show an error message Er255/OC9.
This function restriction has been eliminated with this software modification.