Which products are affected?
ESP-SPAC-CAM1 – Software Package Cam V2.0 (LenzeCamControl1V0200.lib library)
Function description
Up to now, the actual position has been indicated incorrectly at the L_CamControl function block (L_CamControl.dnActPos_p signal) after mains connection in combination with absolute position feedback systems and inverted motor mounting position (L_CamControl.bMotMountingOrientation = TRUE) . As of library version 2.0 the actual position is now also indicated correctly if the inverted motor mounting position has been selected.