Which products are affected?
8200 vector/motec, starttec, 9300 Servo, ECS, Drive and Servo PLC with
- EMF 2102IB V004 (Lecom A) communication module HW ≥ 3G
- E82ZBL-C hand terminal HW ≥ 3G
Eliminated function restriction
We have been able to eliminate the sporadically occurring communication interruption between host / laptop and the EMF 2102IB communication module.
The communication interruption has been caused by an impermissible high current consumption of some hosts / laptops due to which the maximum current of the voltage supply of the basic device has been exceeded sporadically. Since the communication module could temporarily not supply enough current, the communication has been interrupted sporadically.
The use of new, energy-saving components and the reduction of the voltage supply protect against exceeding the maximum current load.