Compilation error when the Lenze8200Drive.lib library is used

Which products are affected?
ESP-DDS2-x (Drive PLC Developer Studio V2.3)

What happens?
If a DDS project which contains the Lenze8200Drive.lib library is compiled the message box indicates the following error message:

Error 3780: L_8200Parameter (65): 'VAR', 'VAR_INPUT','VAR_OUTPUT' or 'VAR_IN_OUT' expected

When does the problem occur?
If the 'Nested comments' option in the 'Compilation options' category of the 'Options' dialog (menu item: Project>Options) is active, the error message mentioned before is indicated in the DDS message box during the compilation process.

Possible diagnostics?
None.

Short-term measures/recommendations?
Deactivate the 'Nested comments' option in the 'Compilation options' category of the 'Options' dialog (menu item: Project>Options).

Evaluation:
Error messages are indicated during the compilation process if the 'Nested comments' option is active and the Lenze8200Drive.lib library is used. The DDS project cannot be loaded in the PLC target system.