Which products are affected?
ESP-SPAC-WND1 - Software Package Winder V2.0 (Template and sample program)
ESP-SPAC-WND1 - Software Package Winder V2.2 (Template and sample program)
How is the reaction?
After compilation there is the following error message:
1. Error 3781: WinderVisualisation: 'End_Var' or identifier expected
2. Error 3782: WinderVisualisation: Unexpected end
When does the problem occur?
The problem only occurs if in DDS 2.x under <Project> => <Option> => <Build< the option 'Nested comments' is activated.
Possible diagnostics?
After compilation of the project the error messages listed above will occur.
Short-term measures/recommendations?
In the created project do not use any nested comments and deactivate the option 'Nested comments' under DDS.
Evaluation:
The restriction only occurs when a project is created and can be avoided by the described measure. This restriction will be eliminated in the next version of the Software Package Winder.