Error message when transferring parameter sets by using the GD Loader

Which products are affected?

EVS93xx-EI (Servo PLC Version 6.3 DSMC control board)
EVS93xx-ET (Servo PLC Version 6.3 DSMC control board)
EPL-10200-EI (Drive PLC Version 6.3)

What happens?

The GD Loader interrupts the parameter set transfer (*.gdc file).

When does the problem occur?

The problem occurs when downloading a parameter set file (*.gdc) which should be loaded into the drive in addition to the DDS binary file (*.bin).

Possible diagnostics?

None.

Short-term measures/recommendations?

Use the Global Drive Control operating software when downloading a *.gdc file.

Evaluation:

At present the GD Loader cannot be used to download machine data sets which comprise a PLC project (*.bin) and a parameter set file (*.gdc) at the same time. This function restriction will be eliminated with the next version.

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/20034007/1/