Download cancellation while setting parameters via EMF2172IB AIF (elimination)

Which products are affected?

Global Drive Loader Version 1.2
EMF2171IB (CAN with hardware-addressing version 1B.12)

Function restriction corrected:

The transfer rate during parameter download can be reduced via an adjustable delay time independent from the PC's performance. Corresponding to the delay time the download is not cancelled anymore when parameters are set via EMF2172IB AIF module.
The delay time can be set in the configuration file GDLoader.ini via the key TransferDelay in milliseconds. The default setting is 1 ms.

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/20031217/1/
Contact form