Difference description 2175IB SW V0.8 to V0.9
1. Product identification
- article number new (V0.9): 421049
- construction labelling new: 2175IB.VB.09 or 2175IB.VC.09
- ordering designation: EMF2175IB
- article number old (V0.8): 403940 or 416657
2. Function improvements
Application
When using the communication profile 'CanOpen' writing and reading jobs are to be carried out simultaneously via parameter channels SDO1 and SDO2.
Description
Fault indications will occur if a block transfer is carried out via one parameter channel and reading or writing jobs are transferred simultaneously via the other parameter channel.
Elimination
With software version V0.9 these fault indications do not occur when using both parameter channels simultaneously.
Short-term measure in the previous version
None
Possible diagnostics
If fault indications are generated during a block transfer the behaviour described above will occur (provided that data is transferred simultaneously on the other parameter channel).