Question:
How long is the response time of the 8200 vector DC injection brake?
Answer:
The DC injection brake is activated via terminal (response time ca. 250 ms):
If the function DC injection brake is activated via a dig in, an internal impulse inhibit is activated in order to de-excite the machine for approx. 250 ms, before a DC voltage or a DC is impressed.
Auto DC injection brake above frequency = 5 Hz (response time ca. 250 ms):
If the function auto DC injection brake is activated via the auto DC injection brake threshold with frequency > 5 Hz, an internal impulse inhibit is activated in order to de-excite the machine for approx. 250 ms, before a DC voltage or a DC is impressed.
Auto DC injection brake below frequency = 5 Hz (response time immediately):
If the function auto DC injection brake is activated via the auto DC injection brake threshold with frequency < 5 Hz, a DC voltage or a DC is impressed in the machine immediately.