The CAN Sync signal is no longer sent after power-on

     

Fixed as of: 
V1.15.2.4096
V2.1.x.xxxx

Behaviour in the new version: 
After saving the parameter set and subsequently performing a CANopen ‘Reset Communication’ or restarting the device, the configured transmission of the SYNC signal remains active. The configured cycle time and the COB-ID of the SYNC telegram, including the enable bit, are correctly applied. The device then resumes transmitting the SYNC telegrams at the configured cycle time.
___________________________________________________________________________________________________________________________________

Date of availability:

V1.15.2.4096
V2.1.x.xxxx

Reference to official Cert@VDE advisory: 
Not applicable. The behaviour described does not constitute a security vulnerability.

Installation of the patch:
Update the device to one of the above-mentioned firmware versions or a newer, released version.

Dependencies:
This behaviour relates to the use of the i950 with the CANopen fieldbus as a CAN SYNC producer.

Proof of use: 
The installed firmware version can be checked via the device identification. To verify functionality, the CAN SYNC transmission can be configured, the parameter set saved and then a CANopen ‘Reset Communication’ executed. Afterwards, the activation bit in the COB-ID of the SYNC telegram must remain set and the device must send the SYNC telegrams with the configured cycle time.

Risks if the patch is not applied:   
If the device is used as a CANopen SYNC producer, SYNC production may be deactivated after the parameter set has been saved and a subsequent ‘Reset Communication’ or device restart has taken place. In this case, no cyclic SYNC telegrams are sent. CANopen participants whose communication depends on the SYNC telegram may therefore not operate synchronously as intended.

Description of behaviour: 
When the ‘Send cyclic SYNC’ function is enabled, the activation bit of the SYNC-COB-ID is not correctly retained after the parameter set has been saved and CANopen communication has subsequently been reinitialised. The configured cycle time and the SYNC identifier are retained, but SYNC generation is deactivated. The device therefore does not send cyclic SYNC telegrams.

Conditions under which the behaviour occurs: 
This behaviour occurs when a CAN SYNC cycle time is configured, the device is enabled as a SYNC producer, and the parameter set is saved. Following a subsequent CANopen ‘Reset Communication’ or a device restart, SYNC production is no longer enabled.

Affected products: 
i950 REV1 and i950 REV2 with CANopen fieldbus and a firmware version prior to the corrected firmware versions mentioned above.

Short-term measure, recommendations, assessment: 
It is recommended to update to one of the firmware versions listed above or a newer, approved version. Until the firmware update is carried out, you should check whether the device is sending the cyclic SYNC telegrams after each time the parameter set is saved and after each reinitialisation of CANopen communication. If SYNC transmission is deactivated, it must be reactivated.