c5xx, c430, i950: Technical Specifications and Profinet Communication Options

Question:
What are the technical specifications and communication options for the Profinet interface of the i950 servo drive and the c430 and c5xx controllers?
 
Answer:
The Profinet module of the i950servo drive differs from the Profinet module of the c5xx controller.
The Profinet module of the i950 servo drive CANNOT be usedin thec5xx controller. 
The Profinet module of the c5xx controller canbe used inthe i950 servo drive.

 

​

​​i950 servo drive

​c5xx Controller

c430 Controller

​Process data width

​16 DWORD inputs
16 DWORD outputs 
(fixed)

​1 ... 250 bytes of inputs per slot
1 ... 250 bytes of outputs per slot
max. 244 slots
Max. 1,440 bytes of process data inputs 
Max. 1,440 bytes of process data outputs

 

​Type Communication module (0x2002:010)

​I9MAFR00000000

​C5MAFR00000000

 Not required (on-board)

 


What types of communication are possible via the Profinet module?

​Servo drive i950

​Controller c5xx

Controller c430

​Notes

​Profinet Process Data Object (PDO)

​Yes

​Yes

 Yes

​

​Profinet parameter channel SDO

​Yes

​No

 No

PROFIenergy

​Yes

​No

 No

​

​PLC Designer 

​Yes, via port 11740

​​Yes, via port 11740

 Yes, via port 11740

​i950, c5xx: Establish a PLC Designer connection via ProfiNet

​Easy-Starter

Yes, via PROFINET (plus OPC UA for c4xx, c5xx, i950 (V2.0 and later))

​Yes

 Yes

​

Easy-Starter Gateway Ethernet/EtherCAT

​Not available

​Yes

 Yes

​

​Application Loader / Firmware Loader

​Yes

​​Yes

 Yes

​

​OPC-UA

​No

​Yes

 Yes

​

​CAA Net Base Services (TCP / UDP)

​No

​No

 No

​

​Network variables (UDP)

​No

​No

 No

​

​Easy-UI Visualization

Not available

No​

 Yes (without encryption)

​

​VisiWinNET Visualization

Not available

​No

 No

​

NTP (Network Time Protocol)

Yes

Yes

Yes

 

 


[Automatic Translation]
URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/202300231/1/