The i550 inverter sends emergency telegrams to the Lenze controller (corrected with V4.2)

     

Fixed as of:

PLC Designer V4.2

 

Behavior of the new version: 

When an i550 inverter is added, the emergency telegrams are disabled in theEtherCAT parameters. As a result, no emergency telegrams are sent from the i550 slave to the EtherCAT master and, consequently, not to the Lenze Error Management of the Lenze controller. 


Description of the behavior: 

Error messages from the i550 inverter are also sent to the EtherCAT master as emergency telegrams.


Conditions under which the behavior occurs: 

After being added to the PLC project, the i550 inverter is configured to send all error messages to the controller as emergency telegrams.


Affected products: 

PLC Designer V4.0


Short-term measures, recommendations, assessment: 

Set parameter 0x285C:010 (Alarm Suppression: Entry 10) of the i550 inverter to the value '0xFFFFFFFF'.


[Automatic Translation]
URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/202600159/1/