L_TS2P_TechModulesSynchronizingCamming (from V3.34.0)
Behavior of the new version:
The parameter scPar.lrSensorToolDistance can be changed at any time during operation. From the next touch probe event, the new value is used to calculate the marker error.
Description of behavior:
Due to the changes to “scPar.lrSensorToolDistance,” the next cut should be precise.
The inaccuracy persists. The new value is only applied after the next change from “xSyncIn= FALSE” to “TRUE.”
Conditions under which the behavior occurs:
1. Activate TM
2. eCuttingMode= Length cutting with mark correction OR Cutting on mark
3. Start cut with xSyncIn=TRUE
4. Change scPar.lrSensorToolDistance during the cut, as this causes inaccuracies in the cut.
Affected products:
Library L_TS2P_TechModulesSynchronizingCamming
Short-term measure, recommendations, assessment:
None
[Automatic Translation]