TA SyncAndCorrection: Synchronization not possible after OperationEnabled=FALSE (fixed as of V1.14.0)

     

Fixed as of: 

i950 servo drive (as of FW1.14.0)


Behavior of the new version: 

Synchronization is automatically restarted when xEnableOperation = TRUE is set. This also works if xSyncIn remains set permanently beyond the controller lockout time.

 

Description of the behavior: 

If synchronization was interrupted by xEnableOperation = TRUE/FALSE, subsequent operation (xEnableOperation = TRUE) cannot be restarted with a rising edge of xSyncIn = FALSE/TRUE.


Conditions under which the behavior occurs: 

Subsequent operation starts only if the rising edge of xEnableOperation = FALSE/TRUE follows the falling edge of xSyncIn = TRUE/FALSE.


Affected products: 

i950 servo drive with TA Sync And Correction (0x4000:0 = [41])

 

Short-term measures, recommendations, assessment: 

Do not reset xEnableOperation until xSyncIn has already been set to FALSE.
[Automatic Translation]