L_TT1P_PickAndPlace: Movement does not start after xExecute = TRUE (fixed as of V3.30.0)

Removed from:
L_TT1P_TechnologyModules_LM  (as of V3.30.0)
(Update via Easy Package Manager)

Behavior of the new version:
The profile is run again if it was previously canceled via xStopAll.


Description of the behavior:
With xExecutePickAndPlace, the profile is not executed.

Conditions under which the behavior occurs:

  • the chained profile is stopped with xStopAll
  • in the Stop state, xAbort is requested
  • in the Ready state, a new profile is then requested with xExecutePickAndPlace

 
Affected products:
Library L_TT1P_TechnologyModules_LM

Short-term measures:
The linked profile can alternatively via the function xPathStop or xPathHalt can be stopped.

Alternatively:
Commission the xAbort function from the READY state before the next profile is started. 

Recommendations, Rating:
DThe affected function restriction only affects the technology module L_TT1P_PickAndPlaceHigh and not -State or -Base. 