TA project templates: Fieldbus PDO mapping not available in V1.8 (fixed from V1.8.0.29)

Corrected from:
PLC Designer device description for i950 V01.08.00.29
(Update via Easy Package Manager)
Behavior of the new version:

When inserting a new i950 TA project template, the fieldbus PDO mapping is available again.



Description of the behavior:

If a new project based on a TA project template is created with the PLC Designer for the i950 V01.08, the fieldbus PDO mapping is not available. It is therefore not possible to control this created TA via the fieldbus interface.

Conditions under which the behavior occurs:

  • creating a new i950 TA based on a TA project template

 
Affected products:
Servo inverter i950 in conjunction with a TA project template (V1.8.0.27)

Short-term measures, Recommendations, Rating:
PLCD device descriptions (package manager) update.