FAST UI Runtime - Alarm Line: ERROR_LEM and FAULT_LEM alarms are not shown in alarm line. Alarm classes must set manually in alarm line

Fixed as of:
Behavior of the new version:


Description of behavior:
If the FAST Framework is enabled in the Project Configurator, an easyuil.lpk is connected, and a LEM alarm is triggered in the PLC, alarms of the classes "ERROR_LEM" and "FAULT_LEM" are not displayed by default in the AlarmLine.

 

Conditions under which the behavior occurs:

  • Setting up a new EASY UI Designer project
  • Enabling the FAST Framework in the Project Configurator
  • Triggering a LEM alarm in the PLC

 
Affected products:
EASY UI Designer >V1.5


Short-term measures, Recommendations, Assessment:
To ensure that alarms of the"ERROR_LEM" and "FAULT_LEM" alarm classes are displayed in the "AlarmLineItem" control, these two entries must be manually added to the "Desired alarm classes" property. The entry will then look like this: System alarm, Alarm, ERROR_LEM, FAULT_LEM.

[Automatic Translation]