FW download from controller to i950 incorrect if the original i950 description was less than V01.08

Fixed from:
Currently, no correction is planned.
 

Description of the behavior:

A firmware download from the Lenze Motion Controller to the i950 via FoE is not performed successfully. 

Under what conditions does the behavior occur?

  • The device description of an i950 EtherCAT slave in the PLC Designer project of the Lenze Motion Controller was updated at some point in the past from a version lower than V01.08 to  V1.10 or higher 
  • A firmware download is activated in the 'Firmware/Parameter set' tab of the i950 EtherCAT slave.
  • The version of the Lenze Motion Controller is V1.12 or higher

Affected products:
All PLC Designer versions

Short-term measures / evaluation / recommendations:

If the i950 EtherCAT slave is not updated to V01.10 or greater, but is newly inserted, then the behavior does not occur 