i950 Holding brake Parameter 0x2820:023=[0], [1], [2]: Selection texts do not match the function (fixed from V01.09.01)

Lifted from:
Servo inverter i950 FW:    from V01.09.01
Related device description file
 
Behavior of the new version:
brake control parameter 0x2820:23: 
In the device description of the new version, the selection texts for the configuration of the brake output are now correctly assigned to the selection numbers again.

 
description of the behavior:
brake control:
In parameter 0x2820:23 for configuration of the brake output, the selection texts of the two selection numbers [0] and [2] are mixed up and partly incorrect.
The swap refers only to the displayed selection texts. The "actual function" assigned to the individual selection numbers remains unaffected:  

0x2820:23= [0]:
  • Actual function:   Internal brake control
  • selection text:                   "External digital output"

0x2820:23= [1]:

  • Actual function:   External components at the brake output
  • selection text:                  "External components at the brake output"

0x2820:23= [2]:

  • Actual function:   External components at the digital output
  • selection text:                   "Internal brake voltage"
Under what conditions does the behavior occur?
  • Parameterization via the engineering tools (device description file) and 
  • use of the i750 firmware version listed under "affected products".
  • Affected products:
    Servo Inverter i950 FW:   V01.08.00 affected
     
    Short-term measures / Evaluation / recommendations:
    The setting of the parameter 0x2820:23 to configure the brake output according to the "actual function" described above, regardless of the swapped selection texts.