i750 Holding brake Parameter 0x2820:023=[0], [1], [2]: Selection texts do not match the function (fixed from V01.02.00)
Lifted from:
Servo Inverter i750 FW: from V01.02.00 Related device description file
Behavior of the new version:
brake control parameter 0x2820:23: In the device description of the new version, the selection texts for the configuration of the brake output are now correctly assigned to the selection numbers again.
Description of behavior: brake-control: In parameter 0x2820:23 for configuration of the brake output, the selection texts of the two selection numbers [0] and [2] are interchanged and partly incorrect. The swap refers only to the displayed selection texts. The "actual function" assigned to the individualselection numbers remains unaffected:
0x2820:23= [0]:
Actual function: Internal brake control
Select text: "External digital output"
0x2820:23= [1]:
Actual function: External components at the brake output
selection text: "External components at the brake output"
0x2820:23= [2]:
Actual function: External components at the digital output
selection text: "Internal brake voltage"
Under what conditions does the behavior occur?
Parameterization via the engineering tools (device description file) and
Using the i750 firmware version listed under "affected products".
Affected products:
Servo-Inverter i750 FW: only V01.01.00 affected
Short-term measures / Evaluation / Recommendations: The setting the parameter 0x2820:23 to configure the brake output according to the "actual function" described above, regardless of the swapped selection texts.